[ Industrial heat intelligence ]

Monitor every heat asset.
Recover every megawatt.

Exertic clamps non-invasive sensors onto your heat exchangers and steam traps, then uses AI to detect fouling and failures the moment they begin — before the bill arrives.

SYS · ONLINE·--:--:-- UTC·EU868 / GKE
exertic / live-pipeline• LIVE
01 / HEAT EXCHANGERINLETOUTLET78.4°C54.1°CΔ 24.3°C02 / LORAWANGATEWAY 0303 / AI ANALYSISEFFECTIVENESS92%FOULING TREND · STABLEFINDING · 000Effectiveness within bandHX-04 · BASELINE 0.91 · NO ACTION
DEVICE EUI · A8404152C8910011RSSI · -84 dBmSF7 / 868.3 MHz
// 01
~0%

of all industrial energy losses come from heat exchanger fouling and steam trap failure.

// 02
0 - 0%

of steam traps are leaking at any given moment without proactive monitoring.

// 03
€0B

in annual heat losses across global industry from exchanger fouling.

[ The problem ]

Fouling and leaking traps silently
drain your energy budget.

P-01

Lost production capacity

Fouled exchangers reduce throughput and force unplanned downtime windows you can't recover.

P-02

Reactive maintenance

Schedule-based servicing costs 3–5× more than condition-based intervention.

P-03

Wasted energy

A single 5 MW exchanger at 20% fouling burns through €480k of fuel per year.

P-04

CO₂ overrun

Every kilowatt of waste heat translates directly to unnecessary scope-1 emissions.

[ How it works ]

From clamped sensor to autonomous insight —
without touching your IT network.

EXERTIC.PIPELINE• LIVE
01 / HEAT EXCHANGERINLETOUTLET78.4°C54.1°CΔ 24.3°C02 / LORAWANGATEWAY 0303 / AI ANALYSISEFFECTIVENESS92%FOULING TREND · STABLEFINDING · 000Effectiveness within bandHX-04 · BASELINE 0.91 · NO ACTION
01

Clamp on

Non-invasive temperature sensors attach to inlet and outlet pipes in minutes. No process shutdown. No pipe cutting.

02

Transmit

LoRaWAN to cellular gateway. Zero IT integration, zero firewall exceptions. Gateway runs on cellular.

03

Analyse

Continuous anomaly detection across LMTD, effectiveness, approach temperature, and trap delta-T.

04

Resolve

Findings route to your CMMS with severity, baseline, and projected ROI of intervention.

[ The solution ]

Non-invasive sensors.
Real-time analysis. No IT integration.

SENSOR / PT-1000 · SX-04
IP67LoRaWAN5y battery
[ SENSOR PRODUCT SHOT ] PT-1000 · CLAMP-ON
01

Clamp-on install

Attach in under 5 minutes per asset. No shutdown, no pipe penetration, no compliance review.

02

Cellular gateway

LoRaWAN to a single LPS8v2 covers the plant. Cellular backhaul means zero firewall exceptions.

03

Continuous detection

LMTD, effectiveness, and approach temp tracked against rolling baselines — anomalies flagged at source.

04

Engineering-grade data

BigQuery time-series with full audit trail. Export, integrate, or pipe into your existing analytics stack.

// MANIFESTO

We help transform Entropy,
into Balance Sheet Efficiency.

[ The vision ]

An AI-native home for every
industrial heat asset.

01
Heat exchangers
Shell-and-tube, plate, air-cooled
● LIVE
02
Steam traps
Mechanical, thermostatic, thermodynamic
● LIVE
03
Boilers
Feedwater + steam outlet differential
◐ BETA
04
Evaporators
Heat transfer coefficient tracking
◐ BETA
05
Condensers
Surface and contact
○ ROADMAP
06
Economizers
Flue gas recovery monitoring
○ ROADMAP
07
Insulation
Surface temperature mapping
○ ROADMAP
[ Beyond monitoring ]

Not just prediction —
autonomous resolution.

Agentic AI takes alerts through SLA review, CMMS ticketing, service coordination, and ROI accounting — so your engineers stay focused on engineering work.

00:00:00

Anomaly

Effectiveness drift detected on HX-04 against 30-day baseline.

00:00:12

Triage

AI cross-references operating envelope, last clean date, and SLA terms.

00:01:34

Dispatch

Work order opens in your CMMS with severity, evidence and projected ROI.

00:42:08

Resolution

Service complete. Baseline restored. Savings calculated and logged.